G.U. Plumbing

Plumber - Mesa, AZ

Average rating

info

5.00

5.0

based on 10 online reviews

Average rating

info

5.00

5.0

based on 10 online reviews
based on 10 ratings

Project Gallery

A table showing the projects done by the pro

Photo

Project

Date

Description

Cost

Home

Mesa 2013

Nov 2013

Permit Number: BLD2013-05451 Permit Type: Permit Description: RES Res (OTH) -- Plumbing PLUMBING PERMIT TO REPAIR/REPLACE GASLINE DUE TO GAS LEAK AT EXISTING DUPLEX UNITS A & B. INSTALLATION OF 71' OF 1/2' GALVANIZED PIPE ATTACHED TO EXTERIOR OF RESIDENCE TO SERVE 32,000 BTU WATER HEATER, TO BE INSTALLED PER 2006 IPC AND CITY OF MESA GAS REQUIREMENTS. NO METER UPGRADE REQUIRED EXISTING 250 CLASS GAS METER

$600

Mesa, AZ

Phoenix 2013

Aug 2013

Permit Number: 13018113 Permit Type: RES MECH OR PLMB Permit Description: GAS LINE NEW INSTALLATION NEW GAS LINE EFFECTIVE BUILDING CODES: 2012 IRC, 2012 IECC, 2012 IBC, 2011 NEC, 2012 IMC, 2012 IPC, 2012 IFC, 2012 IFGC. PRESSURE TEST REQUIRED PER UNIFORM PLUMBING CODE 1204.3.2. TEST TO REMAIN ON SYSTEM UNTIL VERIFIED BY CITY INSPECTOR. APPLIANCES SHALL BE LISTED AND LABELED FOR THE APPLICATION IN WHICH THEY ARE USED. 2012 IPC ( ) PIPE SIZE AND LENGTH:...... 88LF OF 1 1/4', 9LF OF 1/2' TOTAL BTU'S:.... 307K ZONING:......... S-1 REVIEWER:....... TKMA DESCRIPTION OF WORK: INSTALLATION OF APPROVED GAS PIPE PER CURRENT PLUMBING CODE AND REGULATIONS.

$4k

Phoenix, AZ

Plumbing Services Mesa 2011

Dec 2011

Permit Number: BLD2011-05064 Permit Type: Permit Description: RES Res (OTH) -- Plumbing OTC PLUMBING PERMIT: REPLACE GAS LINE - LIKE FOR LIKE

$2k

Mesa, AZ

Phoenix 2007

Jun 2007

Permit Number: 07012936 Permit Type: RES MECH OR PLMB Permit Description: GAS LINE NEW INSTALLATION INSTALL NEW GAS LINE FOR BBQ EFFECTIVE BUILDING CODES: 2003 IBC, 2003 IRC, 2003 IMC, 2003 IECC (As amended by the 2004 supplement), 2005 NEC, ARIZONA STATE PLUMBING CODE, 2003 IFC PRESSURE TEST REQUIRED PER UNIFORM PLUMBING CODE 1204.3.2. TEST TO REMAIN ON SYSTEM UNTIL VERIFIED BY CITY INSPECTOR. PIPE SIZE:......3/4' (15' OFF OF EXISTING GAS LINE) MAX. LENGTH:....119' TOTAL BTU'S:....275 K (45K BBQ, FURNACE 80K, 110K FURNACE, 40K WTR HTR) ZONING:.........R1-8 REVIEWER:.......AFL DESCRIPTION OF WORK: INSTALLATION OF APPROVED GAS PIPE PER CURRENT PLUMBING CODE AND REGULATIONS. ALL WORK SUBJECT TO FIELD INSPECTORS APPROVAL.

$700

Phoenix, AZ

Phoenix 2005

Apr 2005

Permit Number: 05011338 Permit Type: RES MECH OR PLMB Permit Description: REPAIR/REPLACE GAS LINE UPGRADE GAS LINE EFFECTIVE BUILDING CODES: 1997 UBC, 1994 UPC STATE, 2000 UMC, 1999 NEC, 1997 UFC PRESSURE TEST REQUIRED PER UNIFORM PLUMBING CODE 1204.3.2. TEST IS TO REMAIN ON SYSTEM UNTIL VERIFIED BY CITY INSPECTOR. LINEAL FEET:....42' ZONING:.........R1-6 REVIEWER:.......DHUN DESCRIPTION OF WORK: REPLACE EXISTING GAS LINE WITH APPROVED PIPE PER CURRENT PLUMBING CODE AND REGULATIONS. UPGRADE TO 1' TO HANDLE LOAD TO FURNACE. SEE ATTACHED ISOMETRIC. **ALL WORK SUBJECT TO FIELD INSPECTORS APPROVAL**

$1k

Phoenix, AZ

Phoenix 2005

Jan 2005

Permit Number: 05000743 Permit Type: RES MECH OR PLMB Permit Description: GAS LINE NEW INSTALLATION NEW GAS LINE EFFECTIVE BUILDING CODES: 1997 UBC, 1994 UPC STATE, 2000 UMC, 1999 NEC, 1997 UFC PRESSURE TEST REQUIRED PER UNIFORM PLUMBING CODE 1204.3.2. TEST TO REMAIN ON SYSTEM UNTIL VERIFIED BY CITY INSPECTOR. BBQ FIRE PLACE PIPE SIZE:......3/4' MAX. LENGTH:....35' TOTAL BTU'S:....95K ZONING:.........R-2 REVIEWER:.......JGAR DESCRIPTION OF WORK: INSTALLATION OF APPROVED GAS PIPE PER CURRENT PLUMBING CODE AND REGULATIONS. PER PHONE CONVERSASION CUSTOMER SAID 43'OF GAS PIPE. PER PLOT PLAN SHOWS 34.87'. WITH 3/4' PIPE GAS LINE WILL WORK FOR BOTH. ************ALL WORK SUBJECT TO FIELD INSPECTORS APPROVAL**************

$800

Phoenix, AZ

Phoenix 2002

May 2002

Permit Number: 02009736 Permit Type: RES MECH OR PLMB Permit Description: GAS LINE NEW INSTALLATION NEW GAS LINE 132' OF 1' FOR 80K RANGE EFFECTIVE BUILDING CODES: 1997 UBC, 1994 UPC STATE, 2000 UMC, 1999 NEC, 1997 UFC PRESSURE TEST REQUIRED PER UNIFORM PLUMBING CODE 1204.3.2. SYSTEM MUST HOLD 10# PRESSURE FOR 15 MINUTES. TEST TO REMAIN ON SYSTEM UNTIL VERIFIED BY CITY INSPECTOR. PIPE SIZE:......1' MAX. LENGTH:....132' TOTAL BTU'S:....80000 ZONING:.........R1-10 CONTACT/PHONE:..LYNN 602-861-0303 REVIEWER:.......IAN 602-534-9680 DESCRIPTION OF WORK: INSTALLATION OF APPROX 132' OF 1' APPROVED GAS PIPE FOR 80000 BTU RANGE PER CURRENT PLUMBING CODE AND REGULATIONS.

$3k

Phoenix, AZ

Peoria 2009

Feb 2009

Permit Number: 0900239 Permit Type: Residential Permit Description: Miscellaneous Residential 100' N/G GASTITE 1 FROM MTR TO DRYER/RANGE 125K B

Peoria, AZ

Plumbing Services Mesa 2006

May 2006

Permit Number: BLD2006-05612 Permit Type: Permit Description: RES Res (OTH) -- Plumbing PLUMBING PERMIT TO INSTALL 1 NEW SERVICE AT EACH UNIT. 4 UNITS TOTAL (101, 102, 201, AND 202). NO PLANS REQUIRED

Mesa, AZ