We offer a huge amount of savings to our customers through ENERGY TRUST OF OREGON. Home performance Testing. ENERGY REDUCING SOLUTIONS! We do everything from changing your faucets to low flow all the way up to geothermal and everything in between!! Our Purpose is to reduce your energy consumption by a minimum of 30% with incentives to pick up the bill and we do all the paper work for you!! FIND OUT HOW YOU CAN START SAVING MONEY TODAY
18 years in business
Average rating
Address
PO Box 22857
Milwaukie, OR 97269
Photo | Project | Date | Description | Cost | Home |
---|---|---|---|---|---|
![]() ![]() | Oil to Gas Conversion | Feb 2015 | Oil to gas conversion. Installation of Bryant 925TS 60,000BTU 96% gas furnace with Honeywell PRO4000 thermostat. Dispose of old equipment. Reconnect existing electrical. Permit and drawing. New Vent. Condensate removal. Connect to existing ductwork. Pump oil out. | $5k | Portland, OR |
![]() ![]() | Air Conditioner Installation with New Heat Run and New Return Air | Feb 2015 | Installation of Bryant Air Conditioner model 113ANA 2 TON 13 SEER with a 2 TON cased coil .New heat run added upstairs New return air added upstairs | $4k | Portland, OR |
Oil to Gas Conversion | Feb 2015 | Install new Bryant 95%, 80,000BTU Model#915SA48080S17. Install gas pipe to furnace with stub at furnace for future range stub. Hook up existing line voltage and control voltage. Fabricate new sheet metal transitions. Install new filter door with filter rack. Remove existing equipment. Install new PVC venting directly to the outside at driveway with concentric kit. | $3k | Portland, OR | |
Furnace and Air Conditioner Installation | Feb 2015 | Install New Bryant 96% 2 stage gas furnace with ECM motor Model #925TA48080E17. Install New Bryant 2.5 ton air conditioner with new coil and line set ran. Model#113ANA030000. Dispose of existing equipment, reconnect electrical, run new electrical to AC, New vents ran for furnace, new condensate pump, new equipment pad for AC, connect to existing duct work, modify cooling coil into existing duct work. | $6k | Portland, OR | |
Installation of New Furnace | Feb 2015 | Changed out furnace and installed new Bryant furnace 915SA, 95%. Installed all new PVC venting out side wall. | $3k | Portland, OR | |
Furnace and Air Conditioner Installation With additional gas lines | Feb 2015 | Install new Trane TUH2B060A9V3VB 60,000 BTU variable speed furnace in the attic. Install new Trane AC 4TTR3024G1000A 2ton. New coil to match furnace and AC 2 ton Install complete duct system in attic. Filter grill will be located in hallway. New thermostat located in hallway. Platform built for equipment to sit on horizontal. Install gas lines: range stub, water heater stub, and gas line to the new furnace Electrical installed to the furnace, AC, light and plug in attic for service. Electrical permit New: Pan under equipment in attic, new condensate drain, venting for furnace, new line set ran to new AC, pad for AC, one heat run in each bedroom. living room, dinner room, each bathrrom. One return in hallway | $10k | Milwaukie, OR | |
Oil to gas conversion | Feb 2015 | Remove existing oil furnace and recycle. Install Bryant 915SA 80,000BTU furnace. New electrical circuit ran from panel to new furnace. Permit and drawing. New exhaust and intake vents ran to the outside of home through joist bay. Condensate drain repaired to work properly. New metal transitions fabricated to adapt new furnace to existing ductwork. Recover refrigerant from heat pump to install the coil in the proper location on the new furnace. Weld back up refrigerant lines, charge system and verify the heat pumps proper operation. Increase the duct work heat run that supplies the north bedroom upstairs to get better air flow. Reduce the heat run size in the down stairs bedroom Move the location of the media filter for easy access for changing | $5k | Portland, OR | |
Repair of Tankless Waterheater | Dec 2014 | Customer did not have any hot water. Found the limit switch to be bad. Removed old switch and replaced with new one. | $288 | Oregon City, OR | |
Remove Old and Install New Furnace | Dec 2014 | Removed old furnace and installed a new Bryant 925SA 5ton 80,000BTU furnace. Removed and capped old flu pipe. Installed new PVC pipe outside wall. Added valve and drip leg to gas pipe. | $3k | Portland, OR |