Village Lane Condensor Unit

Apr 2014

Installed new 3 ton Goodman heat pump condenser unit. Repaired electrical whip to unit, Repaired low voltage wiring to unit, Replaced 10amp fuse in air handler, Seal taped air handler duct connections, Hauled off old equipment, Checked temperatures (54 supply / 72 Return), Filed warranty. Charged system with 9lbs of R-22 Refrigerant.

$2k

Calera, AL

Forest Drive Furnace

Nov 2013

Installed new Goodman furnace in crawlspace and removed old furnace.

$800

Trussville, AL

Meadowbrook Gas Pack

Sep 2013

Installed a new 3 ton Goodman gas package unit on rental house. Removed old unit.

$3k

Birmingham, AL

Roebuck Drive Repair

Aug 2014

Replaced 35/5 440VAC run capacitor. Added 1 lbs. of R-22 refrigerant to system. Charged to a 13 degree SH. Replaced run capacitor, Taped up two return ducts that had come apart under the house, Checked temps and voltages.

$105

Birmingham, AL

King James Repair

Aug 2014

HVAC not blowing cool air. Checked unit and repaired burnt compressor wire going to the run capacitor. Unit was cooling properly with 68 degrees registering at the kitchen vents upon completion.

$75

Alabaster, AL

King James Circle Precision Tune-Up

Jun 2014

Serviced HVAC system, Check for leaks, Cleaned outdoor coil, Checked indoor coil (good) Replaced 2 20X20 filters, Checked voltages and capacitor. Added 4 lbs of R-22 Refrigerant to system

$159

Alabaster, AL

1st St Precision Tune-Up

May 2014

Performed a precision tune-up on the air conditioning system. Cleaned outdoor coil, Checked temperatures and refrigerant charge, Checked voltages, Inspected indoor coil, Re-taped indoor coil, Repaired condensation drain line that was pouring water into basement. Thawed unit out and added 2lbs of R-22

$75

Center Point, AL

Roebuck Drive Precision Tune-Up

Apr 2014

Serviced HVAC System, Cleaned condenser unit coil, Checked wiring connections and tightened, Checked refrigerant charge, Checked voltages, Evaluated system - Noted below: Checked furnace under house and noted several items that needed to be addressed.

$100

Birmingham, AL

Cameron Drive Repair

Mar 2014

Installed two new evaporator coils, replaced two damaged air handler cabinet doors, replaced two line sets, charged both systems, replaced two condensate drain lines and pump, sealed existing duct, and serviced three systems.

$3k

Chelsea, AL