Remodeling Contractor - Peoria, AZ
Average rating
5.00
5.0
Average rating
Based in Peoria, RC Opat Construction is a general contractor. They have been providing sunroom construction, home addition, and bathroom remodeling as well as other services for 10 years. RC Opat Construction provides emergency services. In June of 2011, they finished a kitchen remodel using a permit received from the city of Phoenix. In December 2009, RC Opat Construction completed a gas line installation using a permit also acquired from the city of Phoenix.
Average rating
Address
8181 W Gelding Dr
Peoria, AZ 85381
Photo | Project | Date | Description | Cost | Home |
---|---|---|---|---|---|
Phoenix 2014 | Jan 2014 | Permit Number: 14001935 Permit Type: RES ELEC Permit Description: UPGRADE ELECTRICAL SERVICE REPLACE 200AMP/3 PHASE PANEL EFFECTIVE BUILDING CODES: 2012 IRC, 2012 IECC, 2012 IBC, 2011 NEC, 2012 IMC, 2012 IPC, 2012 IFC, 2012 IFGC. SERVICE INSTALL PER CURRENT ELECTRICAL CODE. ZONING:.........R1-14 REVIEWER:.......TKK CONTACT YOUR ELECTRIC SERVICE PROVIDER TO VERIFY ANY ADDITIONAL PANEL REQUIREMENTS. DESCRIPTION OF WORK: INSTALL 200AMP; 120/240VOLT; 3 PHASE; 3 WIRE SERVICE. | $5k | Phoenix, AZ | |
Phoenix 2013 | Jun 2013 | Permit Number: 13011068 Permit Type: RES ELEC Permit Description: ELECTRIC WORK AS DESCRIBED REPLACE THE EXISTING 200 AMP SES EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC ZONING:......... PAD10 REVIEWER:....... SWO CONTACT YOUR ELECTRIC SERVICE PROVIDER TO VERIFY ANY ADDITIONAL PANEL REQUIREMENTS. DESCRIPTION OF WORK: REPLACE THE EXISTING 200 AMP SES WITH NEW. ALL WORK SUBJECT TO FIELD INSPECTORS APPROVAL. **** SUITE 9 ONLY *********** | $3k | Phoenix, AZ | |
Glendale 2012 | Mar 2012 | Permit Number: 12003374 Permit Type: RES MECH OR PLMB Permit Description: GAS LINE NEW INSTALLATION GAS LINE EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC PRESSURE TEST REQUIRED PER UNIFORM PLUMBING CODE 1204.3.2. TEST TO REMAIN ON SYSTEM UNTIL VERIFIED BY CITY INSPECTOR. APPLIANCES SHALL BE LISTED AND LABELED FOR THE APPLICATION IN WHICH THEY ARE USED. PIPE SIZE:......3/4' MAX. LENGTH:....95' TOTAL BTU'S:....162,500 ZONING:.........R1-6 REVIEWER:.......CJI DESCRIPTION OF WORK: INSTALLATION OF APPROVED GAS PIPE PER CURRENT PLUMBING CODE AND REGULATIONS. INSTALL 48' OF NEW SCHEDULE 40 GAS PIPE TO A GAS RANGE AT THE KITCHEN PER APPR GAS ISOMETRIC. | $2k | Glendale, AZ | |
Phoenix 2011 | Oct 2011 | Permit Number: 11016427 Permit Type: OTC ELEC Permit Description: NEW OR UPGRADE ELECTRICAL ( ) ADD SWITCHGEAR & PANELS EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC BUSINESS NAME:..OHLINGER INDUSTRIES SES SIZE:.......3000, 480Y/277 ZONING:.........A-1 REVIEWER:.......MVA/DDOV DESCRIPTION OF WORK: ADD SWITCHGEAR & PANELS PER APPROVED PLANS. | $48k | Phoenix, AZ | |
Range Hood Installation Chandler 2011 | Sep 2011 | Permit Number: TNT11-0898 Permit Type: Commercial-Tenant Improvement-Regular Permit Description: NON-RESIDENTIAL ADD/ALT/CONVERSION A-2 Assembly, restaurants, bars, banquet halls THE SUSHI ROOM THE SUSHI ROOM/ INSTALLATION OF ANSUL KITCHEN HOOD FIRE SYSTEM | $1k | Chandler, AZ | |
Chandler 2010 | Aug 2011 | Permit Number: TNT11-0383 Permit Type: Commercial-Tenant Improvement-Regular Permit Description: 437-NON-RESIDENTIAL ADD/ALT/CONVERSION COAL BURGER COAL BURGER / HOOD SUPPRESSION SYSTEM | $1k | Chandler, AZ | |
Range Hood Installation Chandler 2010 | Aug 2011 | Permit Number: TNT11-0292 Permit Type: Commercial-Tenant Improvement-Regular Permit Description: 437-NON-RESIDENTIAL ADD/ALT/CONVERSION GRIMALDI'S GRIMALDI'S / INSTALLATION OF ANSUL KITCHEN HOOD FIRE | $2k | Chandler, AZ | |
Phoenix 2011 | Jun 2011 | Permit Number: 11010192 Permit Type: OTC STRUC/ELEC Permit Description: MISCELLANEOUS KITCHEN REMODEL EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC TYPE OF BUSINESS:KITCHEN REMODEL - UNIT 101 SITE INSP(N) SPECIAL EGRESS CONTROL (N) SPRINKLERS (N) FIRE ALARM (N) EMERGENCY LIGHTING (N) ELEVATORS (N) DEFERRED SUBMITTAL (N) SPEC PER PCC SEC. 1704 (N) STR SEC. 1709 (N) ELEC PCC SEC. 2703 (N) ELEC OBS PCC SEC. 2704 (N) WATER METERS: SECONDARY BACKFLOW (N) SCOPE OF WORK: BLDG ELEC ZONING:R-4 REVIEWER:JLIN DESCRIPTION OF WORK: REMODEL KITCHEN AREA. REMOVE INTERIOR BEARING WALL , RELOCATE REFIGERATOR AND RECEPTICLE, NEW CABINETS PER APPROVED PLAN. ALL OTHER APPLIANCES ARE TO REMAIN IN THE SAME LOCATION. *** ALL WORK SUBJECT TO FIELD INSPECTOR'S APPROVAL. | $3k | Phoenix, AZ | |
Chandler 2009 | May 2011 | Permit Number: TNT11-0426 Permit Type: Commercial-Tenant Improvement-Regular Permit Description: 437-NON-RESIDENTIAL ADD/ALT/CONVERSION ASANTE of CHANDLER ASANTE of CHANDLER / HOOD SUPPRESSION SYSTEM | $1k | Chandler, AZ |