Plumber - Phoenix, AZ
Average rating
4.20
4.2
Average rating
I am a full service plumber offering expertise in Water Heater Replacement, Drain Cleaning, Re-piping Services, Sewer Repair, Electronic Problem Locating and much more. We don't drain your pockets!
Average rating
Address
3634 W Dailey St
Phoenix, AZ 85053
Photo | Project | Date | Description | Cost | Home |
---|---|---|---|---|---|
Toilet Reset | Jul 2014 | Toilet Sink Reset | $111 | Glendale, AZ | |
Kitchen Sink Drain | Jul 2014 | Kitchen sink drain. | $100 | Phoenix, AZ | |
Rebair leak and water sevice | Jul 2014 | Repair leak and water service | $106 | Phoenix, AZ | |
Phoenix 2013 | Sep 2013 | Permit Number: 13020354 Permit Type: OTC PLMB Permit Description: GAS LINE NEW INSTALLATION GAS PIPING-UNIT 5 EFFECTIVE BUILDING CODES: 2012 IRC, 2012 IECC, 2012 IBC, 2011 NEC, 2012 IMC, 2012 UPC OR 2012 IPC, 2012 IFC, 2012 IFGC. PRESSURE TEST REQUIRED PER UNIFORM PLUMBING CODE 1204.3.2. TEST TO REMAIN ON SYSTEM UNTIL VERIFIED BY CITY INSPECTOR. APPLIANCES SHALL BE LISTED AND LABELED FOR THE APPLICATION IN WHICH THEY ARE USED. 2012 UPC (X) PIPE SIZE:......1/2'-3/4' MAX. LENGTH:....60' TOTAL BTU'S:....75000 REVIEWER:.......KAL/DMCC DESCRIPTION OF WORK: INSTALLATION OF APPROVED GAS PIPE PER CURRENT PLUMBING CODE AND REGULATIONS. | $2k | Phoenix, AZ | |
Phoenix 2011 | Apr 2013 | Permit Number: 1200683 Permit Type: LARGE PLAN REVIEW-REMODEL Permit Description: | $3.3m | Phoenix, AZ | |
Phoenix 2012 | Mar 2013 | Permit Number: 12023157 Permit Type: ELECTRICAL Permit Description: MISCELLANEOUS WS85450021 ENERGY MGMT SUB METERING EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC TYPE OF BUSINESS:WS85450021 UNION HILLS WTP LOG#:LPRM 1203720 PROJECT#:I-109 SITE INSP(N) SPECIAL EGRESS CONTROL (N)SPRINKLERS (N) FIRE ALARM (N) EMERGENCY LIGHTING (N) ELEVATORS (N) DEFERRED SUBMITTAL (N)SPEC PER PCC SEC. 1704 (N) STR SEC. 1709 (N) ELEC PCC SEC. 2703 (N) ELEC OBS PCC SEC. 2704 (N) WATER METERS: SECONDARY BACKFLOW (N) SCOPE OF WORK: ELEC ZONING: REVIEWER:ROCCO DELUCA 501-1700 DESCRIPTION OF WORK:INSTALL POWER MONITORING EQUIPMENT INTO THE MAIN SWITCHGEAR (4160VAC) LOCATED AR THE FINISHED WATER BUILDING AND NETWORK THE EQUIPMENT BACK TO THE CCS SYSTEM. INSPECTIONS TO BE DONE BY AFP INSPECTORS. | $67k | Phoenix, AZ | |
Phoenix 2011 | Apr 2013 | Permit Number: 1201743 Permit Type: FP COMPRESSED GAS SYSTEM INSTALL/MODIFY Permit Description: COMPRESSED GAS SYSTEM INSTALLATION CL2 PIPING MODIFICATION ( WS85290024) *AFP*AFP*AFP*AFP*AFP*AFP*AFP*AFP*AFP*AFP**AFP*AFP*AFP*AFP*AFP*AFP*AFP*AFP*AFP*AFP* ALL CITY OF PHOENIX REGULATIONS AND THE PHOENIX FIRE CODES SHALL APPLY. SYSTEMS ARE SUBJECT TO FIELD INSPECTION, INSPECTIONS TO BE DONE BY AFP FIRE. TO SCHEDULE CALL CHIP JENKINS 48-72 HRS BEFORE (602) 319-2497. THIS PERMIT SHALL EXPIRE 24 MONTHS FROM THE DATE OF ISSUE. THIS PERMIT ISNOT TRANSFERABLE PLAN LOG NUMBER:LPRR 1200683 (WS85290024) DESCRIPTION OF WORK: INSTALL/MODIFY CL2 PIPING PER APPROVED PLANS ALL WATER AND CL/2 SOLUTION PIPING SHALL BE TESTED @ 1 1/2 TESTS MANUFACTOR SPEC. OR MIN. 100# ALL CL/2 GAS SHALL BE VACUMM TESTED. ALL SHALL BE WITNESS BY FIRE INSPECTOR APPROVED PLANS SHALL BE AVAILABLE AND PERMITS SHALL BE POSTED ON-SITE AT ALL TIMES DURING WHICH WORK AUTHORIZED HEREBY IS IN PROGRESS. INSPECTIONS SHALL NOT BE CONDUCTED IF APPROVED PLANS AND PERMITS ARE NOT ON-SITE. VIOLATION OF THIS REQUIREMENT IS SUBJECT TO A STOP WORK ORDER AND CIVIL/CRIMINAL SANCTIONS AS ALLOWED BY CODE. **** ALL EXISTING FIRE PROTECTION SYSTEMS MUST HAVE REQUIRED ANNUAL INSPECTIONS COMPLETED AND BE FULLY OPERATIONAL PRIOR TO THE APPROVAL OF THIS INSTALLATION.*** ****** THE INSTALLING CONTRACTOR SHALL COMPLETE AND SIGN THE APPROPRIATE CONTRACTOR'S MATERIALS AND TEST CERTIFICATE(S) | $3.3m | Phoenix, AZ | |
Phoenix 2011 | Apr 2013 | Permit Number: 12005520 Permit Type: STRUC/ELEC Permit Description: REMODEL WS85290024 3RD CENTRAFUGE EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC TYPE OF BUSINESS:24TH ST WTP WS85290024 LOG#:LPRR 1200683 PROJECT#:I-109 SITE INSP(N) SPECIAL EGRESS CONTROL (N) SPRINKLERS (Y) FIRE ALARM (N) EMERGENCY LIGHTING (N) ELEVATORS (N) DEFERRED SUBMITTAL (N) SPEC PER PCC SEC. 1704 (Y) STR SEC. 1709 (Y) ELEC PCC SEC. 2703 (N) ELEC OBS PCC SEC. 2704 (N) WATER METERS: SECONDARY BACKFLOW (N) SCOPE OF WORK: BLDG ELEC PFC ZONING: REVIEWER:RICHARD TOSH 501-1119 DESCRIPTION OF WORK:INSTALL A THIRD CENTRIFUGE, EXTEND SOLIDS CONVEYER SYSTEM, INSTALL POLYMER FEED PUMP, MAKE IMPROVEMENTS TO THE RAW WATER AND SETTLED WATER SAMPLE SYSTEM, AND IMPROVE THE AUTOMATION CONTROL OF THE CHLORINE SUPPLY TO THE RESERVOIR NO 2 INLET. INSPECTIONS TO BE DONE BY AFP INSPECTORS. | $3.3m | Phoenix, AZ | |
Phoenix 2013 | Feb 2013 | Permit Number: 13003217 Permit Type: RES MECH OR PLMB Permit Description: NEW WATER METER INSTALLATION WATER SERVICE/METER INSTALL EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC PROJECT NAME:....DUPLEX ZONING:..........R-3 REVIEWER:........CJI DESCRIPTION OF WORK: INSTALLATION OF A NEW 3/4' INCH WATER METER FOR DOMESTIC WATER WITH A 1' BUILDING SUPPLY FOR 12.5 FIXTURE UNITS. | $3k | Phoenix, AZ |