Robert Klob Designs

Architect - Chandler, AZ

Average rating

info

1.60

1.6

based on 12 online reviews

Average rating

info

1.60

1.6

based on 12 online reviews
based on 12 ratings

Project Gallery

A table showing the projects done by the pro

Photo

Project

Date

Description

Cost

Home

Fence Construction Scottsdale 2011

Sep 2011

Permit Number: 179187 Permit Type: Permit Description: RET WALL W/ FENCE

$12k

Scottsdale, AZ

Scottsdale 2011

Sep 2011

Permit Number: 179186 Permit Type: Permit Description: COMMERCIAL NEW

$2.3m

Scottsdale, AZ

Backup Generator Installation Scottsdale 2012

Mar 2012

Permit Number: 183032 Permit Type: Permit Description: TEMP POWER POLE

Scottsdale, AZ

Backup Generator Installation Scottsdale 2012

Feb 2012

Permit Number: 183178 Permit Type: Permit Description: TEMP POWER POLE

Scottsdale, AZ

Phoenix 2002

May 2002

Permit Number: 02002483 Permit Type: PASSENGER HYDRAULIC Permit Description: GTR 2 STOP PASSENGER TRACTION--ELEVINS ROOSEVELT SQUARE -- ELEVATORS Hydraulic Elevator Acceptance Report Working psi:320 Relief psi:400 Empty Load psi:200 Pressure Switch:n/a F.L. Speed Up:140fpm F.L. Speed Down:130fpm Piston Clearance:15' Buffer Type:Spring Stroke:2.5' Top Car Runby:11' Bottom Car Runby:6.5' Under Car Space:35.5' Top Car Clearance: ' Top Refuge Space:43' Cab Dimension:80'X58' Cab Height: ' Door Type:Side Slide Opening Width:42' Pressure:26lbs Door Close Time - Hall Call:5seconds Car Call:3seconds Prenotification time:In Car Audible Cues:Yes Signage:Yes Disconnect Type:Shunt Breaker Size:125amps FLA:53amps HP:40 Voltage:480volts Emergency Power Type:n/a Fire Service Key:AS100 Comments: Green Tag Issued by:Gregg Spero Date:23-Feb-2001

Phoenix, AZ

Phoenix 2002

May 2002

Permit Number: 02002496 Permit Type: PASSENGER HYDRAULIC Permit Description: GTR 2 STOP PASSENGER TRACTION--ELEVINS ROOSEVELT SQUARE -- ELEVATORS Hydraulic Elevator Acceptance Report Working psi:250 Relief psi:320 Empty Load psi:150 Pressure Switch:n/a F.L. Speed Up:150fpm F.L. Speed Down:153fpm Piston Clearance:16.5' Buffer Type:Spring Stroke:2.5' Top Car Runby:11' Bottom Car Runby:7' Under Car Space: ' Top Car Clearance:44' Top Refuge Space:44' Cab Dimension:80'X58' Cab Height: ' Door Type:Side Slide Opening Width:42' Pressure:26lbs Door Close Time - Hall Call:5seconds Car Call:3seconds Prenotification time:In Car Audible Cues:Yes Signage:Yes Disconnect Type:Shunt Breaker Size:125amps FLA:78amps HP:60 Voltage:480volts Emergency Power Type:n/a Fire Service Key:AS100 Comments: Bldg A #1 5stop Green Tag Issued by:Gregg Spero Date:23-Feb-2001

Phoenix, AZ

Phoenix 2002

May 2002

Permit Number: 02002477 Permit Type: PASSENGER HYDRAULIC Permit Description: GTR 2 STOP PASSENGER TRACTION--ELEVINS ROOSEVELT SQUARE -- ELEVATORS Hydraulic Elevator Acceptance Report Working psi:310 Relief psi:400 Empty Load psi:190 Pressure Switch:n/a F.L. Speed Up:147fpm F.L. Speed Down:149fpm Piston Clearance:12' Buffer Type:Spring Stroke:2.5' Top Car Runby:10' Bottom Car Runby:6' Under Car Space:36' Top Car Clearance:53.5' Top Refuge Space:43.5' Cab Dimension:57.5'X78' Cab Height: ' Door Type:Side Slide Opening Width:42' Pressure:26lbs Door Close Time - Hall Call:5seconds Car Call:3seconds Prenotification time:In Car Audible Cues:Yes Signage:Yes Disconnect Type:Shunt Breaker Size:125amps FLA:53amps HP:40 Voltage:480volts Emergency Power Type:n/a Fire Service Key:AS100 Comments: Green Tag Issued by:Gregg Spero Date:23-Feb-2001

Phoenix, AZ

Phoenix 2002

May 2002

Permit Number: 02002490 Permit Type: PASSENGER HYDRAULIC Permit Description: GTR 2 STOP PASSENGER TRACTION--ELEVINS ROOSEVELT SQUARE -- ELEVATORS Hydraulic Elevator Acceptance Report Working psi:300 Relief psi:340 Empty Load psi:200 Pressure Switch:n/a F.L. Speed Up:142fpm F.L. Speed Down:118fpm Piston Clearance:14' Buffer Type:Spring Stroke:2.5' Top Car Runby:10' Bottom Car Runby:6' Under Car Space:36' Top Car Clearance:39' Top Refuge Space:52' Cab Dimension:80'X52' Cab Height: ' Door Type:Side Slide Opening Width:42' Pressure:15lbs Door Close Time - Hall Call:5seconds Car Call:3seconds Prenotification time:In Car Audible Cues:Yes Signage:Yes Disconnect Type:Shunt Breaker Size:125amps FLA:53amps HP:40 Voltage:480volts Emergency Power Type:n/a Fire Service Key:AS100 Comments: Green Tag Issued by:Ron Fedak #411 Date:23-Feb-2001

Phoenix, AZ

Phoenix 2002

May 2002

Permit Number: 02002487 Permit Type: PASSENGER HYDRAULIC Permit Description: GTR 2 STOP PASSENGER TRACTION--ELEVINS ROOSEVELT SQUARE -- ELEVATORS Hydraulic Elevator Acceptance Report Working psi:340 Relief psi:422 Empty Load psi:200 Pressure Switch:n/a F.L. Speed Up:140fpm F.L. Speed Down:130fpm Piston Clearance:14' Buffer Type:Spring Stroke:2.5' Top Car Runby:12.25' Bottom Car Runby:6.5' Under Car Space:36' Top Car Clearance:34' Top Refuge Space:52.5' Cab Dimension:80'X58' Cab Height: ' Door Type:Side Slide Opening Width:42' Pressure:21lbs Door Close Time - Hall Call:5seconds Car Call:3seconds Prenotification time:In Car Audible Cues:Yes Signage:Yes Disconnect Type:Shunt Breaker Size:125amps FLA:53amps HP:40 Voltage:480volts Emergency Power Type:n/a Fire Service Key:AS100 Comments: Green Tag Issued by:Kent Reed Date:23-Feb-2001

Phoenix, AZ