We are dedicated to serving your heating and air conditioning needs 24/7 in a manner that continues to serve you satisfactorily far into the future. We have been in business for 30 years performing all types of residential and commercial comfort needs. Reliability, efficiency, personal preference, pricing and popularity dictate which brand of equipment we install. 13 SEER - 14 SEER - 16 SEER systems available. Ensure that your residential commercial heating and air conditioning needs are properly addressed by a licensed team of technicians, no matter where you are in the Dallas area.
Tom N.
03/16/2015
Dennis Moore has always been accessable, on time, friendly, trustworthy, and professional. His work is top notch and his rates are fair. I trust him with all my AC needs.
Address
2913 Lancer Ln
Garland, TX 75044
Photo | Project | Date | Description | Cost | Home |
---|---|---|---|---|---|
![]() ![]() | 3101 Vicki Ct Garland 75044 | Mar 2015 | Replace two air conditioning systems 3 ton 13 SEER refrigerant R-410a 4 ton 14 SEER refrigerant R-410a Furnace + Condenser + Evaporator Thermostat + Base Pads + Filter rack Connections Air Sealed | $11k | Garland, TX |
![]() ![]() | 25 yr Service Satisfaction | Mar 2015 | This property has been serviced by me since I graduated from Air Conditioning College. A second story condenser and an over the tub air handler made it difficult for the condo owner to obtain good service. Condensate line ties to neighbors making it difficult to clean - installed an isolation valve. Refrigerant was leaking - Repaired leak above tub on an evaporator that was impossible to reach. Compressor died - Replaced Condenser and upgraded to 13 SEER. Went through several tenants and eventually a new owner. Satisfaction ensured that they would always call me. Today we rewarded their loyalty with a free service inspection. Provided the owner with a detailed synopsis of current temperatures, amperages, pressures and voltages to provide a baseline for detection of any future system problems or modification requirements. | $1 | Dallas, TX |
![]() ![]() | Residential Air Conditioning system upgrade. | Sep 2012 | Complete system upgrade from 8 seer to 13, R-22 refrigerant to environmentally safe R-410a. Consisting of a Condenser, Evaporator, Furnace, Filter Rack and Thermostat. | $4k | Dallas, TX |
Hair Pro | Aug 2013 | Found unit circuit breaker tripped. Reset breaker and it immediately tripped. Checked power on roof and found one leg not providing power. Traced conduit from unit back to circuit breaker box and found a bad connection at a wire nut in a junction box above the breakroom ceiling. Repaired electrical problem and started unit. Unit was low on refrigerant, so I charged it. Found expansion valve uncovered and exposed to extremely high temperature (this could cause the unit to flood itself and trip the circuit breaker) I reinsulated the expansion valve and secured the insulation. The electrical control box cover in unit was not reinstalled because it no longer would fit so, I cut the cover so it could be put back in place and installed it. The unit access covers we loose and one was allowing hot air to enter the building so, I tightened them to fit and replaced all of the missing screws. Scheduled leak Check in September. | $675 | Garland, TX | |
Condenser Replacement | Jun 2011 | Condenser Replacement | $5k | Richardson, TX | |
Suction Line Condensate Damaged Bedroom Wall | Jul 2010 | Insulated exposed section of refrigerant suction line in bedroom wall. Performed Maintenance Inspection of entire AC system. | $400 | Garland, TX | |
COMMERCIAL Heat Call | Dec 2006 | Checked out heating of rooftop unit. Saw no signs of an uncontrolled fire. Visually inspected heat exchanger, system was functional with no signs of leakage. Turned on heat and observed operation of heating system. Vent fan came on and gas valve engaged, igniter lit the burner and system performed normally. Checked inside building for any sign of smoke or smell, everything was ok. Ran unit for 30 minutes and performed a carbon monoxide test meter did not detect a high level of CO3. The initial lighting of the heating system probably caused some burn off of built up airborne dust on the heat exchanger that when heated caused the smoke detector to go off. Left unit running with thermostat set at 72 degrees. | $275 | Garland, TX | |
Handyman - Room Modifications | Oct 2005 | Installed an arch top inset high in the center of the family room wall to a depth allowable by wall thickness. Drywall will be left untextured and unfinished. Installed a closet approx 2ft X 6ft in corner of room including two bi fold closet doors. Doors and drywall will be left untextured and unfinished. | $2k | Richardson, TX | |
Replace the existing condenser. | Oct 2004 | Provide labor and material to replace the existing condenser a 13 SEER Rheem - condenser. | $3k | Richardson, TX |