Forquer Heating & Air Conditioning, Inc.

HVAC Contractor - North Canton, OH

Average rating

info

4.75

4.7

based on 87 online reviews

Average rating

info

4.75

4.7

based on 87 online reviews
based on 87 ratings

Project Gallery

A table showing the projects done by the pro

Photo

Project

Date

Description

Cost

Home

Air Duct Cleaning

Dec 2015

Using a one ton vacuum truck and high pressure air tool, mechanically cleaned the forced air furnace and air duct system. Clean supply ducts. Clean branch lines. Clean fan compartment. Clean return ducts. Clean fan. Disinfect and deodorize.

Hudson, OH

Aquastat Replacement

Dec 2015

Removed 3 broken Aquastats and replaced with 3 new Honeywell Aquastats. All Aquastats set to engage at 125 degrees.

Akron, OH

Gas valve replacement

Dec 2015

Main gas valve not opening. Loose internal connection on existing ignition module. Replaced ignition module with Honeywell module. Converted pilot assembly from thermocouple to flame sense rod. Cycled furnace to ensure correct operation.

Kent, OH

Boiler Inspection

Dec 2015

Replace pressure relief valve. Drain boiler system. Pipe in new reducing station. Install new expansion tank. Purge air from old system. Put boiler back into service.

Canton, OH

Boiler Install

Dec 2015

Replace boiler. Repair chimney. Install flue liner. Install backflow preventer.

Canton, OH

Furnace Installation

Dec 2015

Install new Concord 45,000 BTU x 80% efficient furnace. Install new 5" chimney liner. Install new Bradford White 40 gallon low boy Hot water tank Replace all existing flue pipe for furnace and hot water tank and tie into chimney liner. Install new White Rodgers digital thermostat.

Akron, OH

Ignitor Installation

Nov 2015

Found ignitor installed wrong. Re-positioned ignitor and set manifold pressure at .25.

Akron, OH

Furnace clean and checks

Nov 2015

Unit #1: Cleaned flame sensor. Replaced air filter. 4.1va, 1.62" / 3.25"wc 39 degree/ 56 degree rise (25-55/ 40-70) 48/27ppm. CO AF, 82%/ 83% efficient. All ok. Unit #2: Cleaned flame sensor. 6.1va, adjusted 2.2" - 3.5"wc, 34ppm CO AF, 82% efficient. All ok. Unit #3: Cleaned flame sensor. 6.0va, 3.25"wc, 43 degree rise (35 degrees - 65 degrees), 47ppm CO AF, 83% efficient. All ok. Unit #4: Cleaned flame sensor. 2.25va, 3.25"wc, speed from Med - Lo to Med-Hi, 52 degree rise, 68ppm CO AF, 81% efficient. All ok.

Akron, OH