General Contractor - Phoenix, AZ
Average rating
5.00
5.0
Average rating
Average rating
Address
3308 W Walter Way
Phoenix, AZ 85027
Photo | Project | Date | Description | Cost | Home |
---|---|---|---|---|---|
Phoenix 2010 | Jul 2011 | Permit Number: 11005 Permit Type: MISC Permit Description: | $205k | Phoenix, AZ | |
Phoenix 2010 | Jul 2011 | Permit Number: 11002973 Permit Type: RES STRUC/MECH OR PLMB/ELEC Permit Description: ADDITION TO EXISTING RESIDENCE ADDITION / REMODEL EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC WORK INVOLVES: STRUCT, ELEC, MECH, PLBG RETENTION REQUIRED. NO - EXEMPT EXISTING WTR MTR:.. 5/8' FIXTURE UNITS:..... 26.7 NEW WTR MTR:....... 3/4' DEV. LENGTH:....... 105' BUILDING SUPPLY:... 1 1/4' WRA:............... 01 ZONING:............ R1-10 HILLSIDE:.......... NO REVIEWER:.......... SWO THE EXISTING DWELLING SHALL BE EQUIPPED WITH SMOKE DETECTORS AS REQUIRED FOR NEW DWELLINGS. THE SMOKE DETECTORS SHALL BE INTERCONNECTED AND HARDWIRED WITH THE EXCEPTIONS AS STATED IN IRC R313.2.1. DESCRIPTION OF WORK: ADDITION OF MASTER BEDROOM, MASTER CLOSET, MASTER BATHROOM, POWDER ROOM, LAUNDRY, STORAGE, TWO-CAR GARAGE, REAR PATIO, BREAKFAST NOOK, ADD BAY WINDOW TO SITTING ROOM IN FRONT OF HOUSE, FRONT PORCH, ADD BAY WINDOW TO BEDROOM #2, AND REMODEL THE EXISTING BEDROOMS 1 & 2, BATHROOM, LIVING ROOM AND KITCHEN FOR THE EXISTING SINGLE FAMILY RESIDENCE PER APPROVED PLANS. *** REV TO ADD 86 LF 6' BLOCK FENCE AND GATE SHOWN ON APPROVED PLANS AT REAR AND SIDE OF HOME. *** | $207k | Phoenix, AZ | |
Phoenix 2009 | Sep 2009 | Permit Number: 09014849 Permit Type: RES MECH OR PLMB Permit Description: MISCELLANEOUS REPLACE HVAC AND DUCTWORK EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC ZONING:.........R1-6 REVIEWER:.......RPE DESCRIPTION OF WORK: REMOVE AND REPLACEMENT OF EXISTING 3 TON HVAC AND DUCTWORK (MIN R-8) FOR A SINGLE FAMILY RESIDENCE. | $6k | Phoenix, AZ | |
Phoenix 2002 | Jun 2003 | Permit Number: 02009104 Permit Type: RES STRUC Permit Description: RETAINING WALL RETAINING WALLS EFFECTIVE BUILDING CODES: 1997 UBC, 1994 UPC STATE, 2000 UMC, 1999 NEC, 1997 UFC THIS PERMIT IS FOR LOT(S) 35 ONLY HEIGHT OF RETAINING WALL ABOVE GRADE LIMITED TO 3'4' MAXIMUM WITHOUT A USE PERMIT FROM PLANNING & ZONING. HEIGHT OF RETAINING WALL PLUS FENCE = 9' MAX FENCE ON TOP OF WALL ()NO (X)YES ZONING:.........R1-8PRD HILLSIDE:.......YES CONTACT/PHONE:..ROBERT MUSCARI/480-695-6166 REVIEWER:.......CCO/MVA DESCRIPTION OF WORK: INSTALLATION OF 73 LF OF 6' HIGH RETAINING WALL. INSTALLATION OF 75 LF OF 3' HIGH RETAINING WALL AND 6' FENCE ON TOP | $8k | Phoenix, AZ | |
Phoenix 2001 | Jun 2003 | Permit Number: 01026252 Permit Type: RES SINGLE FAMILY Permit Description: CUSTOM RESIDENCE CUSTOM RESIDENCE EFFECTIVE BUILDING CODES: 1997 UBC, 1994 UPC STATE, 2000 UMC, 1999 NEC, 1997 UFC LOG NUMBER:........RPRC 01376 ROOFING:...........TILE, ICBO 3748 ATTACHED TO FIELD SET. WATER METER:.......NEW 3/4' x 3/4' MIN. BUILDING SUPPLY:...1' FIXTURE UNITS:.....32 WRA:...............2 PATIO SIZE:........165 GARAGE:............DBL FINISH FLOOR ELEV:.75.5 HILLSIDE:..........NO RETENTION REQUIRED.YES, VOLUME=1463 POST-TENSION SLAB:. NO ZONING:............R1-8PRD CONTACT/PHONE:.....JEFF RUEB 602-692-9040 REVIEWER:..........JST **NOTE: NEW OR ALTERED FIREPLACES PERMITTED AFTER 1-1-99 MUST COMPLY WITH ORDINANCE G4062. DESCRIPTION OF WORK: CONSTRUCTION OF A NEW SINGLE FAMILY RESIDENCE. | $173k | Phoenix, AZ | |
Phoenix 2002 | Dec 2002 | Permit Number: 02020846 Permit Type: RES STRUC/MECH OR PLMB/ELEC Permit Description: REMODEL OF EXISTING RESIDENCE REMODEL EFFECTIVE BUILDING CODES: 1997 UBC, 1994 UPC STATE, 2000 UMC, 1999 NEC, 1997 UFC WORK INVOLVES STRUCT, ELEC, PLMG & MECH. ZONING:.........R-3 REVIEWER:.......PHALL DESCRIPTION OF WORK: REMODEL SFR TO INCLUDE NEW A/C UNIT OF ROOF, BRACE THE CONVENTIONAL ROOF FRAMING FOR THE ADDED WEIGHT PER ENGINEERING. THIS IS FOR THE CASITA. | $3k | Phoenix, AZ | |
Phoenix 2002 | Dec 2002 | Permit Number: 02020843 Permit Type: RES STRUC/MECH OR PLMB/ELEC Permit Description: REMODEL OF EXISTING RESIDENCE REMODEL EFFECTIVE BUILDING CODES: 1997 UBC, 1994 UPC STATE, 2000 UMC, 1999 NEC, 1997 UFC WORK INVOLVES STRUCT, ELEC, PLMG & MECH. ZONING:.........R-3 REVIEWER:.......PHALL DESCRIPTION OF WORK: REMODEL TO INCLUDE INSTALL NEW A/C UNIT, BRACE THE CONVENTIONAL ROOF FRAMING PER ENGINEERING, INSTALL 150 AMP 1PHASE SES. | $5k | Phoenix, AZ | |
Scottsdale 2001 | Jul 2002 | Permit Number: 01019042 Permit Type: RES STRUC/MECH OR PLMB/ELEC Permit Description: ADDITION TO EXISTING RESIDENCE RES ADTN WORK INVOLVES: STRUCT, ELEC, MECH, PLBG RETENTION REQUIRED.YES, 3034 CU FT. ZONING:.........RE-35 HILLSIDE:.......NO CONTACT/PHONE:..MATT HUSTEAD 602-692-4866 REVIEWER:.......THA/CCO DESCRIPTION OF WORK: OMNI BLOCK ADDITION OF 2020sf TO EXISTING SINGLE FAMILY RESIDENCE PER APPROVED PLANS. SCOPE OF WORK INCLUDES 1' WATER METER(44 FUs) W/ 1.5' DIA. WATER SUPPLYLINE FROM THE MTR BOX TO THE HOUSE. INSTALLATION OF THE OMNI BLOCK SHALL COMPLY W/ I.C.B.O. REPORT# ER-4997 REISSUED 3/1/01. ****SPECIAL INSPECTION INCLUDES: STRUCTURAL MASONRY PER UBC 1701.5.& THE OMNI ICBO REPORT, + EPOXIED ANCHORS(ICBO# ER- 5279). A COPY OF THE OMNI BLOCK MFR'S SPEC IS ATTACHED TO THE PLAN PER THE ICBO REPORT. | $180k | Scottsdale, AZ | |
Scottsdale 2002 | Jun 2002 | Permit Number: 02008283 Permit Type: RES ELEC Permit Description: UPGRADE ELECTRICAL SERVICE ELECT UPGRADE EFFECTIVE BUILDING CODES: 1997 UBC, 1994 UPC STATE, 2000 UMC, 1999 NEC, 1997 UFC SERVICE UPGRADE PER CURRENT ELECTRICAL CODE. ZONING:.........RE-35 CONTACT/PHONE:..JEFF RUEB 623-692-9040 REVIEWER:.......KGR DESCRIPTION OF WORK: UPGRADE EXISTING SES TO 400A; 120/240VOLT; 1 PHASE; 3 WIRE SERVICE. | $2k | Scottsdale, AZ |