3620 E Campbell Ave Ste D
Phoenix, AZ 85018
Photo | Project | Date | Description | Cost | Home |
---|---|---|---|---|---|
Scottsdale 2014 | Feb 2014 | Permit Number: 14002467 Permit Type: RES STRUC/MECH OR PLMB/ELEC Permit Description: MISCELLANEOUS FIRE RESTORATION-REPAIR EFFECTIVE BUILDING CODES: 2012 IRC, 2012 IECC, 2012 IBC, 2011 NEC, 2012 IMC, 2012 UPC OR 2012 IPC, 2012 IFC, 2012 IFGC. ZONING:.........R1-14 REVIEWER:.......JST2 THE EXISTING DWELLING SHALL BE EQUIPPED WITH SMOKE DETECTORS AS REQUIRED FOR NEW DWELLINGS. THE SMOKE DETECTORS SHALL BE INTERCONNECTED AND HARDWIRED WITH THE EXCEPTIONS AS STATED IN IRC R313.2.1. DESCRIPTION OF WORK:FIRE DAMAGE REPAIR/RESTORATION INCLUDING NEW ROOF STRUCTURE OVER PORTION OF RESIDENCE, INTERIOR DEMOLITION & SMOKE DAMAGE ABATEMENT. 200 AMP SES REPLACEMENT AND INTERIOR ELECTRICAL, PLUMBING, & MECHANICAL REPAIR. | $222k | Scottsdale, AZ | |
Glendale 2014 | Feb 2014 | Permit Number: 14034 Permit Type: RES PLAN REVIEW - MISC Permit Description: | $45k | Glendale, AZ | |
Glendale 2014 | Jan 2014 | Permit Number: 14000204 Permit Type: RES ELEC Permit Description: PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC EFFECTIVE BUILDING CODES: 2012 IRC, 2012 IECC, 2012 IBC, 2011 NEC, 2012 IMC, 2012 UPC OR 2012 IPC, 2012 IFC, 2012 IFGC. ZONING:R1-8 REVIEWER:PJO HISTORIC PRESERVATION: ( ) YES ( X ) NO QUANTITY & SIZE OF PANELS: 24 61 X 41 WEIGHT OF PANELS: 2.77 PSF EXISTING ROOF FRAMING: ( ) CONVENTIONAL ( X ) TRUSS ( ) OTHER: ____________ DESCRIPTION OF WORK: INSTALLATION OF __7.84____ KW PHOTOVOLTAIC SYSTEM PER APPROVED PLANS AND SPECIFICATIONS. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER NEC 690.17, 690.64(B)(4) AND 705.10. FEE OPTION: ( ) VALUATION-BASED ( ) FIXED FEE OPTION A - 3 INSPECTIONS ( ) FIXED FEE OPTION B - 2 INSPECTIONS ( ) FIXED FEE OPTION C - 2 INSPECTIONS ( X ) FIXED FEE OPTION D - 1 INSPECTION ( ) FIXED FEE OPTION E - 1 INSPECTION *IF ADDITIONAL INSPECTIONS ARE REQUIRED, RE-INSPECTION FEES WILL BE ASSESSED BY THE FIELD INSPECTOR | $43k | Glendale, AZ | |
Phoenix 2013 | Dec 2013 | Permit Number: 13026255 Permit Type: RES ELEC Permit Description: PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC EFFECTIVE BUILDING CODES: 2012 IRC, 2012 IECC, 2012 IBC, 2011 NEC, 2012 IMC, 2012 UPC OR 2012 IPC, 2012 IFC, 2012 IFGC. ZONING:R-2 REVIEWER:PJO HISTORIC PRESERVATION: ( ) YES ( X ) NO QUANTITY & SIZE OF PANELS: 21 65 X 39 WEIGHT OF PANELS: 2.33 PSF EXISTING ROOF FRAMING: ( ) CONVENTIONAL ( X ) TRUSS ( ) OTHER: ____________ DESCRIPTION OF WORK: INSTALLATION OF ___6.87___ KW PHOTOVOLTAIC SYSTEM PER APPROVED PLANS AND SPECIFICATIONS. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER NEC 690.17, 690.64(B)(4) AND 705.10. FEE OPTION: ( ) VALUATION-BASED ( ) FIXED FEE OPTION A - 3 INSPECTIONS ( ) FIXED FEE OPTION B - 2 INSPECTIONS ( ) FIXED FEE OPTION C - 2 INSPECTIONS ( X ) FIXED FEE OPTION D - 1 INSPECTION ( ) FIXED FEE OPTION E - 1 INSPECTION *IF ADDITIONAL INSPECTIONS ARE REQUIRED, RE-INSPECTION FEES WILL BE ASSESSED BY THE FIELD INSPECTOR | $25k | Phoenix, AZ | |
Glendale 2013 | Nov 2013 | Permit Number: 13024404 Permit Type: RES ELEC Permit Description: PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC EFFECTIVE BUILDING CODES: 2012 IRC, 2012 IECC, 2012 IBC, 2011 NEC, 2012 IMC, 2012 IPC, 2012 IFC, 2012 IFGC. ZONING: R1-8 REVIEWER: RMUR HISTORIC PRESERVATION: ( ) YES ( X ) NO QUANTITY & SIZE OF PANELS: (30) 5.5' X 3.28' WEIGHT OF PANELS: 3.03 PSF EXISTING ROOF FRAMING: ( ) CONVENTIONAL ( X ) TRUSS ( ) OTHER: ____________ DESCRIPTION OF WORK: INSTALLATION OF 7.95 KW PHOTOVOLTAIC SYSTEM PER APPROVED PLANS AND SPECIFICATIONS. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER NEC 690.17, 690.64(B)(4) AND 705.10. FEE OPTION: ( ) VALUATION-BASED ( ) FIXED FEE OPTION A - 3 INSPECTIONS ( ) FIXED FEE OPTION B - 2 INSPECTIONS ( X ) FIXED FEE OPTION C - 2 INSPECTIONS ( ) FIXED FEE OPTION D - 1 INSPECTION ( ) FIXED FEE OPTION E - 1 INSPECTION *IF ADDITIONAL INSPECTIONS ARE REQUIRED, RE-INSPECTION FEES WILL BE ASSESSED BY THE FIELD INSPECTOR | $24k | Glendale, AZ | |
Phoenix 2013 | Nov 2013 | Permit Number: 13024489 Permit Type: RES STRUC/MECH OR PLMB/ELEC Permit Description: ADDITION TO EXISTING RESIDENCE RESIDENTIAL ADDITION / REMODEL EFFECTIVE BUILDING CODES: 2012 IRC, 2012 IECC, 2012 IBC, 2011 NEC, 2012 IMC, 2012 UPC OR 2012 IPC, 2012 IFC, 2012 IFGC. WORK INVOLVES: STRUCT, ELEC, MECH, PLBG RETENTION REQUIRED: NO - HOUSE BUILT IN 1959 ZONING:......... R1-10 HILLSIDE:....... NO REVIEWER:....... SRA DESCRIPTION OF WORK: ADDITION/EXPAND (84 SQ. FT.), MASTER BATHROOM AND FRONT ENTRY, INTERIOR REMODEL (1500 SQ. FT.) AND REWIRE (1270 SQ. FT.), TO THIS EXISTING ONE STORY SINGLE FAMILY RESIDENCE; EXISTING CMU CONSTRUCTION; ADDITION IS WOOD FRAME SLAB-ON-GRADE CONSTRUCTION; GASLINE; NEW 200 AMP ELECTRIC PANEL, PER APPROVED PLANS AND STRUCTURAL ANALYSIS. NO NEW PLUMBING FIXTURES TO BE ADDED. FIELD TO VERIFY. THE EXISTING DWELLING SHALL BE EQUIPPED WITH SMOKE DETECTORS AS REQUIRED FOR NEW DWELLINGS. THE SMOKE DETECTORS SHALL BE INTERCONNECTED AND HARDWIRED WITH THE EXCEPTIONS AS STATED IN IRC R313.2.1. | $77k | Phoenix, AZ | |
Phoenix 2013 | Oct 2013 | Permit Number: 13022256 Permit Type: RES ELEC Permit Description: PHOTOVOLTAIC SYSTEM EFFECTIVE BUILDING CODES: 2012 IRC, 2012 IECC, 2012 IBC, 2011 NEC, 2012 IMC, 2012 UPC OR 2012 IPC, 2012 IFC, 2012 IFGC. ZONING:R1-6 ************* NEW SERVICE / UPGRADE **************** REVIEWER:PJO HISTORIC PRESERVATION: ( ) YES ( X ) NO QUANTITY & SIZE OF PANELS: 32 65 X 39 WEIGHT OF PANELS: 2.69 PSF EXISTING ROOF FRAMING: ( X ) CONVENTIONAL ( ) TRUSS ( ) OTHER: ____________ DESCRIPTION OF WORK: INSTALLATION OF ___8.3___ KW PHOTOVOLTAIC SYSTEM PER APPROVED PLANS AND SPECIFICATIONS. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER NEC 690.17, 690.64(B)(4) AND 705.10. FEE OPTION: ( ) VALUATION-BASED ( ) FIXED FEE OPTION A - 3 INSPECTIONS ( ) FIXED FEE OPTION B - 2 INSPECTIONS ( ) FIXED FEE OPTION C - 2 INSPECTIONS ( X ) FIXED FEE OPTION D - 1 INSPECTION ( ) FIXED FEE OPTION E - 1 INSPECTION *IF ADDITIONAL INSPECTIONS ARE REQUIRED, RE-INSPECTION FEES WILL BE ASSESSED BY THE FIELD INSPECTOR | $25k | Phoenix, AZ | |
Tolleson 2013 | Sep 2013 | Permit Number: 13019616 Permit Type: RES ELEC Permit Description: PHOTOVOLTAIC SYSTEM INSTALL NEW PHOTOVOLTAIC SYSTEM EFFECTIVE BUILDING CODES: 2012 IRC, 2012 IECC, 2012 IBC, 2011 NEC, 2012 IMC, 2012 UPC OR 2012 IPC, 2012 IFC, 2012 IFGC. ZONING: R1-6PRD REVIEWER: RMUR HISTORIC PRESERVATION: ( ) YES (X) NO QUANTITY & SIZE OF PANELS: (32) 61 X 41 WEIGHT OF PANELS:2.69 PSF EXISTING ROOF FRAMING: ( ) CONVENTIONAL (X) TRUSS ( ) OTHER: ____________ DESCRIPTION OF WORK: INSTALLATION OF 10.41 KW PHOTOVOLTAIC SYSTEM PER APPROVED PLANS AND SPECIFICATIONS. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER NEC 690.17, 690.64(B)(4) AND 705.10. FEE OPTION: ( ) VALUATION-BASED ( ) FIXED FEE OPTION A - 3 INSPECTIONS ( ) FIXED FEE OPTION B - 2 INSPECTIONS (X) FIXED FEE OPTION C - 2 INSPECTIONS ( ) FIXED FEE OPTION D - 1 INSPECTION ( ) FIXED FEE OPTION E - 1 INSPECTION *IF ADDITIONAL INSPECTIONS ARE REQUIRED, RE-INSPECTION FEES WILL BE ASSESSED BY THE FIELD INSPECTOR | $40k | Tolleson, AZ | |
Phoenix 2013 | Aug 2013 | Permit Number: 13018363 Permit Type: RES ELEC Permit Description: PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC EFFECTIVE BUILDING CODES: 2012 IRC, 2012 IECC, 2012 IBC, 2011 NEC, 2012 IMC, 2012 UPC OR 2012 IPC, 2012 IFC, 2012 IFGC. ZONING:R1-8 REVIEWER:LTA/EWA HISTORIC PRESERVATION: ( ) YES ( X ) NO QUANTITY & SIZE OF PANELS: (38) 21X WEIGHT OF PANELS: 3.3 PSF EXISTING ROOF FRAMING: ( ) CONVENTIONAL ( X ) TRUSS ( ) OTHER: ____________ DESCRIPTION OF WORK: INSTALLATION OF __345____ KW PHOTOVOLTAIC SYSTEM PER APPROVED PLANS AND SPECIFICATIONS. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER NEC 690.17, 690.64(B)(4) AND 705.10. FEE OPTION: ( ) VALUATION-BASED ( ) FIXED FEE OPTION A - 3 INSPECTIONS ( ) FIXED FEE OPTION B - 2 INSPECTIONS ( ) FIXED FEE OPTION C - 2 INSPECTIONS ( X ) FIXED FEE OPTION D - 1 INSPECTION ( ) FIXED FEE OPTION E - 1 INSPECTION *IF ADDITIONAL INSPECTIONS ARE REQUIRED, RE-INSPECTION FEES WILL BE ASSESSED BY THE FIELD INSPECTOR | $50k | Phoenix, AZ |