Apple Plumbing Services

Plumber - Phoenix, AZ

Average rating

info

4.69

4.7

based on 1,448 online reviews

Average rating

info

4.69

4.7

based on 1,448 online reviews
based on 1,448 ratings

Project Gallery

A table showing the projects done by the pro

Photo

Project

Date

Description

Cost

Home

Scottsdale 2013

Jan 2013

Permit Number: 13001482 Permit Type: RES MECH OR PLMB Permit Description: GAS LINE NEW INSTALLATION ADD GAS BRANCH LINE TO NEW STOVE EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC PRESSURE TEST REQUIRED PER UNIFORM PLUMBING CODE 1204.3.2. TEST TO REMAIN ON SYSTEM UNTIL VERIFIED BY CITY INSPECTOR. APPLIANCES SHALL BE LISTED AND LABELED FOR THE APPLICATION IN WHICH THEY ARE USED. PIPE SIZE:...... 3/4' CSST MAX. LENGTH:.... 90 TOTAL BTU'S:.... 151,000 ZONING:......... R-4 REVIEWER:....... GBU DESCRIPTION OF WORK: INSTALLATION OF APPROVED GAS PIPE PER CURRENT PLUMBING CODE AND REGULATIONS.

$1k

Scottsdale, AZ

Phoenix 2012

Nov 2012

Permit Number: 12022969 Permit Type: RES MECH OR PLMB Permit Description: REPAIR/REPLACE GAS LINE GAS SYSTEM SIZE AND CLEARANCE EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC PRESSURE TEST REQUIRED PER UNIFORM PLUMBING CODE 1204.3.2. TEST IS TO REMAIN ON SYSTEM UNTIL VERIFIED BY CITY INSPECTOR. LINEAL FEET:....40'MAX ZONING:.........R1-6 REVIEWER:.......CJI/JLAN DESCRIPTION OF WORK: REPAIR OR REPLACE EXISTING GAS LINE WITH APPROVED PIPE PER CURRENT PLUMBING CODE AND REGULATIONS. SIZED GAS SYSTEM WITH COMBO SCHEDULE 40 PIPE AND CORRUGATED STEEL PIPE. SEE APPR GAS ISOMETRIC. GAS CLEARANCE NEEDED.

$2k

Phoenix, AZ

Phoenix 2012

Jan 2012

Permit Number: 12000346 Permit Type: RES MECH OR PLMB Permit Description: REPAIR/REPLACE GAS LINE (ONLINE ONLY) REPAIR/REPLACE GAS LINE EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC(cid:13) (cid:13) PRESSURE TEST REQUIRED PER UNIFORM PLUMBING CODE 1204.3.2. REQUIRED GAUGE FACE MUST HAVE 1/10 POUND INCREMENT. TEST IS TO REMAIN ON SYSTEM UNTIL VERIFIED BY CITY INSPECTOR.(cid:13) (cid:13) DESCRIPTION OF WORK: REPAIR OR REPLACE EXISTING GAS LINE WITH APPROVED PIPE PER CURRENT PLUMBING CODE AND REGULATIONS. ***** LOT #

$300

Phoenix, AZ

Phoenix 2011

Dec 2011

Permit Number: 11021290 Permit Type: RES MECH OR PLMB Permit Description: REPAIR/REPLACE GAS LINE GAS REPAIR EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC PRESSURE TEST REQUIRED PER UNIFORM PLUMBING CODE 1204.3.2. TEST IS TO REMAIN ON SYSTEM UNTIL VERIFIED BY CITY INSPECTOR. LINEAL FEET:....5' ZONING:.........N/A REVIEWER:.......DANCIL DESCRIPTION OF WORK: REPAIR OR REPLACE EXISTING GAS LINE WITH APPROVED PIPE PER CURRENT PLUMBING CODE AND REGULATIONS.

$650

Phoenix, AZ

Phoenix 2011

May 2011

Permit Number: 11009601 Permit Type: RES MECH OR PLMB Permit Description: REPAIR/REPLACE GAS LINE RELOCATE GAS LINE EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC PRESSURE TEST REQUIRED PER UNIFORM PLUMBING CODE 1204.3.2. TEST IS TO REMAIN ON SYSTEM UNTIL VERIFIED BY CITY INSPECTOR. LINEAL FEET:.... 5 ZONING:......... R1-6 REVIEWER:....... SRA DESCRIPTION OF WORK: REPAIR OR REPLACE OR RELOCATE EXISTING GAS LINE WITH APPROVED PIPE PER CURRENT PLUMBING CODE AND REGULATIONS. GAS LINE IS MOVING CLOSER TO APPLIANCES (WATER HEATER AND DRYER). FIELD TO VERIFY.

$900

Phoenix, AZ

Phoenix 2010

Oct 2010

Permit Number: 10009944 Permit Type: RES MECH OR PLMB Permit Description: GAS LINE NEW INSTALLATION NEW GAS LINE EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC PRESSURE TEST REQUIRED PER UNIFORM PLUMBING CODE 1204.3.2. TEST TO REMAIN ON SYSTEM UNTIL VERIFIED BY CITY INSPECTOR. APPLIANCES SHALL BE LISTED AND LABELED FOR THE APPLICATION IN WHICH THEY ARE USED. PIPE SIZE:......2', 1-1/2' PE AND STEEL MAX. LENGTH:....130' TOTAL BTU'S:....525K FOR POOL HEATER AND BBQ ZONING:.........R1-10AL REVIEWER:.......RPE DESCRIPTION OF WORK: INSTALLATION OF APPROVED GAS PIPE PER CURRENT PLUMBING CODE AND REGULATIONS.

$5k

Phoenix, AZ

Phoenix 2010

Jul 2010

Permit Number: 10013815 Permit Type: RES MECH OR PLMB Permit Description: PLUMBING REPIPE REPLACE 70' OF EXISTING WATER SERVICE EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC ZONING:......... R1-6 REVIEWER:....... SWO DESCRIPTION OF WORK: RESIDENTIAL WATER SERVICE 70' REPIPE WITH 1' COPPER PIPE USING APPROVED MATERIALS TO COMPLY WITH CURRENT PLUMBING CODE. ALL WORK SUBJECT TO FIELD INSPECTORS APPROVAL.

$2k

Phoenix, AZ

Phoenix 2009

Sep 2009

Permit Number: 09017140 Permit Type: RES MECH OR PLMB Permit Description: REPAIR/REPLACE GAS LINE GAS LINE REPAIR EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC PRESSURE TEST REQUIRED PER UNIFORM PLUMBING CODE 1204.3.2. TEST IS TO REMAIN ON SYSTEM UNTIL VERIFIED BY CITY INSPECTOR. LINEAL FEET:.... 3 ZONING:......... PAD 8 REVIEWER:....... SRA DESCRIPTION OF WORK: REPAIR OR REPLACE EXISTING GAS LINE WITH APPROVED PIPE PER CURRENT PLUMBING CODE AND REGULATIONS.

$400

Phoenix, AZ

Phoenix 2008

Jul 2008

Permit Number: 08009854 Permit Type: RES MECH OR PLMB Permit Description: MISCELLANEOUS REPLACE / RELOCATE SEWER AND WATER LINES EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2005 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC ZONING:......... R 1-6 REVIEWER:....... SMA DESCRIPTION OF WORK: REPLACE 60 LF OF 4' SEWER LINE AND 60 LF OF 3/4' WATER LINE DUE TO LOCATION OF NEW SWIMMING POOL.

$3k

Phoenix, AZ