Pacific West Solar Hot Water

Plumber - Phoenix, AZ

Project Gallery

A table showing the projects done by the pro

Photo

Project

Date

Description

Cost

Home

Laveen 2013

Sep 2013

Permit Number: 13020577 Permit Type: RES ELEC/MECH OR PLMB Permit Description: SOLAR WATER HEATER SOLAR WATER HEATER EFFECTIVE BUILDING CODES: 2012 IRC, 2012 IECC, 2012 IBC, 2011 NEC, 2012 IMC, 2012 IPC, 2012 IFC, 2012 IFGC. REVIEWER:...... TKMA ZONING:...... R1-8 PRD HISTORIC PRESERVATION: ( )YES ( X )NO (IF YES, CERTIFICATE OF NO AFFECT IS REQUIRED) ROOF MOUNTED COLLECTOR(S): ( X )YES ( )NO QUANTITY & SIZE OF COLLECTOR(S): QTY = 1 SIZE = 4' X 10' ROOF MOUNTED STORAGE TANK: ( )YES ( X )NO WEIGHT OF ROOF MOUNTED SYSTEM WITH COMPONENTS: 4.075 PSF (ROOF MOUNTED SYSTEMS GREATER THAN 5 PSF REQUIRE STRUCTURAL ENGINEERING / CALCULATIONS.) SOLAR RATING CERTIFICATION CORPORATION - ( SRCC ) SRCC CERT 300#: 300-200801A SYSTEM MODEL NAME: FS410-80-1 SYSTEM TYPE: FORCED CIRCULATION DESCRIPTION OF WORK: INSTALLATION OF SOLAR WATER HEATING COLLECTORS. (M2301.2.8) SOLAR LOOP ISOLATION - VALVES SHALL BE INSTALLED TO ALLOW THE SOLAR COLLECTORS TO BE ISOLATED FROM THE REMAINDER OF THE SYSTEM. EACH ISOLATION VALVE SHALL BE LABELED WITH THE OPEN AND CLOSED POSITION. (M2301.2.9) MAXIMUM TEMPERATURE LIMITATION - SYSTEMS SHALL BE EQUIPPED WITH A MEANS TO LIMIT WATER TEMPERATURE OF THE SYSTEM TO 180 DEGREES F. THIS PROTECTION IS IN ADDITION TO THE T&P VALVE REQUIRED BY SECTION M2301.2.3. (M2301.2.3) PRESSURE & TEMPERATURE RELIEF - SYSTEM COMPONENTS CONTAINING FLUIDS SHALL BE PROTECTED WITH T&P VALVES. RELIEF DEVICES SHALL BE INSTALLED IN SECTIONS OF THE SYSTEM SO THAT A SECTION CANNOT BE VALVED OFF OR ISOLATED FROM A RELIEF DEVICE. (M2301.2.2) ROOF MOUNTED COLLECTORS AND SUPPORTS MUST BE NON-COMBUSTIBLE OR OF FIRE RETARDANT TREATED WOOD.

$6k

Laveen, AZ

Glendale 2011

Dec 2011

Permit Number: 11017078 Permit Type: RES ELEC/MECH OR PLMB Permit Description: SOLAR WATER HEATER INSTALL SOLAR WATER HEATER EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC REVIEWER:...................................... RBUN ZONING:........................................ PAD-9 HISTORIC PRESERVATION:......................... NO ROOF MOUNTED COLLECTOR(S):..................... YES QUANTITY & SIZE OF COLLECTOR(S):............... QTY = 1 SIZE = 4' X 10' ROOF MOUNTED STORAGE TANK:..................... NO WEIGHT OF ROOF MOUNTED SYSTEM WITH COMPONENTS: 4.075 PSF (ROOF MOUNTED SYSTEMS GREATER THAN 5 PSF REQUIRE STRUCTURAL ENGINEERING / CALCULATIONS.) SOLAR RATING CERTIFICATION CORPORATION - ( SRCC ) SRCC CERT 300#: 2008001A SYSTEM MODEL NAME: FS410-80-1 SYSTEM TYPE: DIRECT FORCED CIRCULATION DESCRIPTION OF WORK: INSTALLATION OF SOLAR WATER HEATING COLLECTORS. (M2301.2.8) SOLAR LOOP ISOLATION - VALVES SHALL BE INSTALLED TO ALLOW THE SOLAR COLLECTORS TO BE ISOLATED FROM THE REMAINDER OF THE SYSTEM. EACH ISOLATION VALVE SHALL BE LABELED WITH THE OPEN AND CLOSED POSITION. (M2301.2.9) MAXIMUM TEMPERATURE LIMITATION - SYSTEMS SHALL BE EQUIPPED WITH A MEANS TO LIMIT WATER TEMPERATURE OF THE SYSTEM TO 180 DEGREES F. THIS PROTECTION IS IN ADDITION TO THE T&P VALVE REQUIRED BY SECTION M2301.2.3. (M2301.2.3) PRESSURE & TEMPERATURE RELIEF - SYSTEM COMPONENTS CONTAINING FLUIDS SHALL BE PROTECTED WITH T&P VALVES. RELIEF DEVICES SHALL BE INSTALLED IN SECTIONS OF THE SYSTEM SO THAT A SECTION CANNOT BE VALVED OFF OR ISOLATED FROM A RELIEF DEVICE. (M2301.2.2) ROOF MOUNTED COLLECTORS AND SUPPORTS MUST BE NON-COMBUSTIBLE OR OF FIRE RETARDANT TREATED WOOD. **THE ABOVE MENTIONED CODE SECTIONS ARE NOT ALL INCLUSIVE. INSTALLATIONS MUST COMPLY WITH ALL APPLICABLE CODES AS ADOPTED BY THE CITY OF PHOENIX. FIELD INSPECTOR TO VERIFY CODE COMPLIANCE.**

$6k

Glendale, AZ

Phoenix 2011

Apr 2011

Permit Number: 11003154 Permit Type: RES ELEC/MECH OR PLMB Permit Description: SOLAR WATER HEATER SOLAR WH SYSTEM - 4X10 PANEL ROOF MOUNT EFFECTIVE BUILDING CODES: 2006 IRC, 2006 IECC, 2006 IBC, 2008 NEC, 2006 IMC, 2006 UPC, 2006 IFC, 2006 IFGC REVIEWER:...... GBU ZONING:........ R1-10 HISTORIC PRESERVATION: ( )YES ( X )NO ROOF MOUNTED COLLECTOR(S): ( X )YES ( )NO QUANTITY & SIZE OF COLLECTOR(S): QTY = 1 SIZE = 4' X 10' ROOF MOUNTED STORAGE TANK: ( )YES ( X )NO EXISTING ROOF FRAMING: ( )CONVENTIONAL ( X )TRUSS WEIGHT OF ROOF MOUNTED SYSTEM WITH COMPONENTS: 4.0 PSF (ROOF MOUNTED SYSTEMS GREATER THAN 5 PERCENT DESIGN LOADS REQUIRE STRUCTURAL ENGINEERING / CALCULATIONS.) SOLAR RATING CERTIFICATION CORPORATION - ( SRCC ) MODEL: FS410-80-1 COLLECTOR TYPE: DIRECT FORCED CIRCULATION CERTIFICATION #: 300-2008001-A DESCRIPTION OF WORK: INSTALLATION OF SOLAR WATER HEATING COLLECTORS. (M2301.2.8) SOLAR LOOP ISOLATION - VALVES SHALL BE INSTALLED TO ALLOW THE SOLAR COLLECTORS TO BE ISOLATED FROM THE REMAINDER OF THE SYSTEM. EACH ISOLATION VALVE SHALL BE LABELED WITH THE OPEN AND CLOSED POSITION. (M2301.2.9) MAXIMUM TEMPERATURE LIMITATION - SYSTEMS SHALL BE EQUIPPED WITH A MEANS TO LIMIT WATER TEMPERATURE OF THE SYSTEM TO 180 DEGREES F. THIS PROTECTION IS IN ADDITION TO THE T&P VALVE REQUIRED BY SECTION M2301.2.3. (M2301.2.3) PRESSURE & TEMPERATURE RELIEF - SYSTEM COMPONENTS CONTAINING FLUIDS SHALL BE PROTECTED WITH T&P VALVES. RELIEF DEVICES SHALL BE INSTALLED IN SECTIONS OF THE SYSTEM SO THAT A SECTION CANNOT BE VALVED OFF OR ISOLATED FROM A RELIEF DEVICE. (M2301.2.2) ROOF MOUNTED COLLECTORS AND SUPPORTS MUST BE NON-COMBUSTIBLE OR OF FIRE RETARDANT TREATED WOOD.

$6k

Phoenix, AZ

Chandler 2014

Jan 2014

Permit Number: RSM14-0013 Permit Type: Residential Miscellaneous Permit Description: SINGLE FAMILY 5892 W GAIL DR, HOLMES RESIDENCE 5892 W GAIL DR HOLMES RESIDENCE / PACIFIC WEST SOLAR FS410-80 1/(1) 4X10 COLLECTOR (1) 80 GALLON STORAGE TANKS

Chandler, AZ

Water Heater Installation Chandler 2013

Oct 2013

Permit Number: RSM13-1113 Permit Type: Residential Miscellaneous Permit Description: SINGLE FAMILY LIPTON LIPTON / SOLAR WATER HEATER FS410-80-1 (1) 4x10 COLLECTOR (1) 80 GALLON TANK

Chandler, AZ

Water Heater Installation Peoria 2013

Sep 2013

Permit Number: 1302993 Permit Type: Permit Description: Miscellaneous Residential PACIFIC WEST SOLAR/NICHOLS SOLAR WATER HEATER (APS)

Peoria, AZ

Peoria 2013

Aug 2013

Permit Number: 1301927 Permit Type: Permit Description: Miscellaneous Residential PACIFIC WEST SOLAR - HAKALMAZIAN SOLAR WATER HEATER SRP

Peoria, AZ

Water Heater Installation Peoria 2013

Jul 2013

Permit Number: 1302199 Permit Type: Permit Description: Miscellaneous Residential PACIFIC WEST SOLAR/MC CONNELL SOLAR WATERHEATER (APS)

Peoria, AZ

Water Heater Installation Peoria 2013

Jun 2013

Permit Number: 1301775 Permit Type: Permit Description: Miscellaneous Residential PACIFIC WEST SOLAR - MULLER SOLAR WATER HEATER

Peoria, AZ