Home

Install 2 ton Fujitsu 17.5 SEER 24,000 BTU 230 volt cooling only unit in Surgery room on right wall.

Oct 2014

This project consists of the following: Surgery Room 175 E. Ft. Lowell Install 2 ton Fujitsu 17.5 SEER 24,000 BTU 230 volt cooling only unit in Surgery room on right wall. This is to add to the existing air condition that is there, to help cool room when in use. Suggest installing condensing unit on roof. Warranty: Seven year compressor, five year parts, one year installation. Bid does not include electrical work from panel to either location, 230 volts and disconnect with breaker supplied by you electrician. A 230 volt, 25 amp breaker is needed.

$5k

Tucson, AZ

Gas Package Unit

Sep 2014

The project consisted of the following: Removal and and properly dispose of existing Ruud gas package unit. Install new 2.5 ton 14 SEER Rheem #RRPLB030JK06XAUA gas package unit. Project details: - two 4'x4' redwood supports - two plenum flex connectors with sunshields - electrical wiring from disconnect box to unit - Honeywell digital thermostat - crane fees - gas flex with shut off - PVC condensate drain line Warranty: 20 year heat exchanger, 10 year compressor and parts, one year installation. One year maintenance included (start up plus one additional maintenence)

$6k

Tucson, AZ

Split System Complete and Operational

Aug 2014

The project consisted of the following: Removing and properly disposing of existing system. Install new 5 ton split system complete and operation. Project details: - New disconnect box with fuses and electrical line from unit to disconnect box. - Sealtite electrical box for thermostat wire with thermostat wire to furnace and a/c unit from thermostat. - Electrical line cord to furnace - Condensate drain lines for proper operation - Filter rack and filter - Single wall flue pipe to existing double wall flue. - New Honeywell thermostat - Plenum modifications for proper operation Rheem 5 ton 16.0 SEER 2 state model #RARL060JEC, Furnace 2 stage variable speed model #RGPE07NBRMR, 5 ton Coil model #RE41660D257B2922AP. Warranty: 10 year compress and parts, one year installation. One year maintenance agreement included (start up plus on additional maintenance)

$10k

Tucson, AZ

Remove and properly recycle existing R22 A/C system and hot water heater

Aug 2014

This project consists of the following: Remove and properly recycle existing R22 A/C system and hot water heater. Included in bid: (one for each new unit) Thermostat, plenum above furnace and coil, filter base and filter, electrical line cord, flue piping, gas flex with shut off valve, PVC condensate drain with secondary safety switch, electrical disconnect with fuses, thermostat wiring seal tight box. Unit #1 West side of house Rheem R410a 5 ton 14.5 SEER cond. #14AJM60A01, furn. #RGPT07NBRQR and matching coil. Unit #2 Rheem R410a 2.5 ton 15.5 SEER cond. #14AJM30A01, furn. #RGPT07NAMKR with matching coil. Unit #3 Northeast side: Rheem R410a 3.5 Ton 15.5 SEER cond #14AJM42A01, furn #RGPT07-NBRQR with matching coil. Warranty: 20 year heat exchangers, ten year compressors and parts, one year installation. North side Water Heater: Replace existing AO smith 40 gallon waater heater with a 40 gallon Rheem water heater. Included in bid: gas flex line with shut off valve, flue piping, three hat water flexes, labor, cap and drain for yearly flushing Warranty: Six years tank and parts, one year installation.

$973

Tucson, AZ

Split System Complete

Aug 2014

The project consisted of the following: Removing and properly disposing of existing system. Install new 5 ton split system complete and operation. Project details: - New disconnect box with fuses and electrical line from unit to disconnect box. - Sealtite electrical box for thermostat wire with thermostat wire to furnace and a/c unit from thermostat. - Electrical line cord to furnace - Condensate drain lines for proper operation - Filter rack and filter - Single wall flue pipe to existing doubel wall flue. - New Honeywell thermostat - Plenum modifications for proper operation Rheem 5 ton 16.0 SEER 2 state model #RARL060JEC, Furnace 2 stage variable speed model #RGPE07NBRMR, 5 ton Coil model #RE41660D257B2922AP Warranty: 10 year compress and parts, one year installation. One year maintenance agreement included(start up plus on additional maintenance)

$9k

Tucson, AZ

2 Rheem Heat Pumps

Aug 2014

This project consists of the following: Remove existing York cooling units, one 3 ton in back and one 4 ton in front. Install new Rheem Heat Pumps using existing duct work. Included in bid: Electrical wiring as needed. Condensate drains as needed. Use existing thermostats. Warranty: Five years on compressors, one year on parts, one year on installation.

$10k

Tucson, AZ

Install new Lennox 5 ton 16 SEER 2 stage heat and cool, variable. Condensing unit model #XC21-060-230-09, furnace

Aug 2014

This project consists of the following: speed blower motor Remove and properly recycle the existing Trane system. Install new Lennox 5 ton 16 SEER 2 stage heat and cool, variable. Condensing unit model #XC21-060-230-09, furnace Model #SL280UH110V60C and coil model #CX34-62C-6F. Included in bid: Electrical disconnect with fuses and wiring to condensing unit. Seal tight box for thermostat wiring. Flue piping Furnace electrical cord Gas flex line with shut off valve PVC condensate drain with safety shut off switch This project consists of the following: speed blower motor Remove and properly recycle the existing Trane system. Install new Lennox 5 ton 16 SEER 2 stage heat and cool, variable. Condensing unit model #XC21-060-230-09, furnace Model #SL280UH110V60C and coil model #CX34-62C-6F. Included in bid: Electrical disconnect with fuses and wiring to condensing unit. Seal tight box for thermostat wiring. Flue piping Furnace electrical cord Gas flex line with shut off valve PVC condensate drain with safety shut off switch This project consists of the following: speed blower motor Remove and properly recycle the existing Trane system. Install new Lennox 5 ton 16 SEER 2 stage heat and cool, variable. Condensing unit model #XC21-060-230-09, furnace Model #SL280UH110V60C and coil model #CX34-62C-6F. Included in bid: Electrical disconnect with fuses and wiring to condensing unit. Seal tight box for thermostat wiring. Flue piping Furnace electrical cord Gas flex line with shut off valve PVC condensate drain with safety shut off switch

$10k

Tucson, AZ

Rheem 40 gallon water heater

Aug 2014

This project consists of the following: Install a second Rheem 40 gallon water heater on the east side of the house. Included in bid: Gas flex line with shut off valve Flue piping Hot water flexes Drain with cap for yearly flushing Labor Warranty: Six year tank and parts One year installation

$831

Tucson, AZ

new Lennox 5 ton split system.

Jul 2014

This project consists of the following: Remove and properly recycle American Standard split system. Install new Lennox 5 ton split system. Included in bid: Electrical disconnect with fuses and wiring to unit Seal tite box for thermostat wiring Armaflex for cooper lines Primary and secondary drain lines Furnace electrical cord Gas flex with shut off valve Furnace filter base with filter Flue pipe Wi Fi thermostat Lennox 16 SEER condenser with 2 stage compressor #XC25-060-230-09, 2 stage variable speed furnace #SL280UH090V60C-iC and coil #L-42/60S-C. Warranty: 20 year heat exchanger, 10 year parts and compressor, one year installation. One year maintenance agreement included (start up plus one additional maintenance)

$10k

Tucson, AZ